Bathrooms and electric showers

Water and electricity need extra care, and bathrooms have their own set of rules to match. From a new electric shower to a full refit with lighting, a demist mirror, an extractor fan and the supply for underfloor heating, Carl makes sure everything is in the right place, with the right rating, and properly certified.

Electric showers, explained

An electric shower heats water as it flows, so it's one of the biggest loads in your house. Pick a power rating and a season to see what it means for the water, and for the wiring.

Pull-cord isolator10 mm² circuit 8.5 kW

Shower power

Time of year

3.5Litres a minute at 40°C
37 ACurrent drawn
40 ATypical circuit breaker
10 mm²Typical cable

Upgrading? Going from 8.5 kW to 10.5 kW means more current. If the old cable or breaker isn't rated for it, connections overheat. We check the whole circuit before you buy the new shower.
Every shower needs isolation. A pull-cord or wall isolator outside the zones lets you turn it off safely for cleaning and maintenance.
RCD protected. All bathroom circuits need 30 mA RCD protection. If your fuse board doesn't have it, we'll sort that too.

Guide only. Sizes, ratings and requirements depend on your property. Carl confirms everything at a survey and in your written quote. About this information

Bathroom zones and IP ratings

BS 7671 splits a bathroom into zones based on how close water gets. Drag the ceiling light along the ceiling, change the ceiling height, or tap anything in the room to see what's allowed where.

2.25 m Zone 0Zone 1Zone 2 Zone 1Zone 2 Outsidethe zones Ceiling void Underfloor heating mat ← drag →
ZoneWhereWhat's needed
Zone 0Inside the bath or shower trayIPX7 and extra-low voltage (12 V SELV) only
Zone 1Above the bath or tray, up to 2.25 mIPX4 minimum (IPX5 where jets are used); 230 V fittings need 30 mA RCD protection
Zone 20.6 m beyond zone 1, up to 2.25 mIPX4 minimum; shaver sockets allowed out of direct spray
Outside the zonesEverywhere else in the roomNo minimum IP rating, but we fit IP44 or better. Standard sockets must be at least 3 m from zone 1

Guide only. Sizes, ratings and requirements depend on your property. Carl confirms everything at a survey and in your written quote. About this information

Demist mirrors

No more wiping the mirror with your sleeve.

A heated pad on the back of the mirror keeps the glass just warm enough that steam can't settle. We wire it to come on with the bathroom light or the extractor fan, so it just works. Most illuminated mirrors now include one, along with an LED surround and sometimes a shaver socket.

  • Wired from the lighting circuit or a fused spur outside the zones
  • IP44 rated for zone 2 or outside the zones
  • Linked to the light or fan so it's never left on

Run the shower, then switch the demister on.

Guide only. Sizes, ratings and requirements depend on your property. Carl confirms everything at a survey and in your written quote. About this information

Fused spurThermostatic element

Electric towel rails

Warm towels, a dry bathroom, and no waiting for the central heating to come on.

An electric towel rail heats on its own, so it works in summer when the boiler is off, and it helps stop damp and mould in a bathroom that never quite dries out. You can have an all-electric rail, or add an electric element to a rail on the heating so it works both ways.

  • Fed from a switched fused spur, with the switch outside the bathroom zones
  • A neat flex outlet behind the rail, so there are no trailing cables
  • Thermostatic or timed elements, so it's only on when you want it
  • RCD protected, tested and certified, with Building Control notified where the rules require it
Real jobSee the real job: electric towel railAn electric towel rail on its own fused spur, with a thermostat element, wired neatly at skirting level.

IP-safe bathroom lighting

The IP rating tells you how well a light keeps out dust (first number) and water (second number). In a bathroom, the water number is what matters.

IP20No water protection. Fine in a bedroom, not in a bathroom's zones.
IP44Splash-proof. The minimum we fit anywhere in a bathroom.
IP65Jet-proof. What we recommend above showers and baths.
IP67 and IP68Immersion-proof, 12 V only. For lights inside baths, niches and wet rooms.
  • Fire-rated downlights to keep the ceiling's fire resistance
  • LED strip in shower niches and under vanity units
  • Low-level night lights on a motion sensor
  • Mirror and cabinet lighting with shaver sockets
  • Extractor fans on a timer or humidity sensor
  • Supplies for electric underfloor heating and heated towel rails

From Carl's job diary

Recent jobs like this, in Carl's own words and photos.

Bathroom

An electric towel rail

Nice little job today, installing a towel rail with an electric heating element. Another happy customer.

Carl, on Facebook
White electric towel rail with a fused spur and thermostat element, installed on a pink tiled bathroom wall in the Wirral

Follow Carl on Facebook for new jobs

What customers say

★★★★★
I would definitely recommend Carl to anyone needing an electrician. We needed a new extractor fan and Carl was able to fit one within a few hours of us first contacting him. The service was speedy, efficient, and very reasonably priced. Can't rate him highly enough.
Andy D.Bathrooms · Google review
★★★★★
Carl rewired both bathrooms and found the previous builder had left the wiring in a lethal state. He was professional, prompt and we have utmost confidence in his work. Best in Wirral.
Peter C.Bathrooms · Google review

Read more reviews · See them all on Google

Tell Carl what you need

Free, no-obligation quotes across the Wirral. Most enquiries get a reply the same working day.